ecom-DPH

ecom-DPH

Click to Enlarge

ecom-DPH Set for the Heating Check acc. to DIN EN 15378

ecom-DPH Measuring Instrument

Measured values: temperature (-50… 300°C), differential pressure (± 10 hPa)

Calculated value: air speed (0,15 m/s… 40 m/s), ventilation and surface losses

Graphic-capable display with window ≈ 43 x 28 mm, resolution 128 x 64 Pixel, backlit

Power supply: 3 current batteries 1.5V (Mignon) or 3 accumulators 1.2V AA NiCd (nickel-
cadmium) or 3 accumulators 1.2V AA NiMh (metal-hydride)

Accumulator charging and instrument operation possible via current USB charger

Dimensions: approx. 170 x 75 x 35 mm (L x B x H) Weight: approx. 300 g

Probe for ventilation losses measurement:

Length approx. 250 mm, probe pipe made out of special steel, with cable 2,6 m and fixation cone

Probe for Surface Losses:
With thermocouple strip, length approx. 210 mm (incl. grip), Ø approx. 16 mm. With cable approx. 1 m (angled probe for hardly accessible measurement points, optio- nal) Magnet fixation for surface losses probe, straight style

Set delivered in robust transport case made out of plastics: Dimensions: approx. 390 x 345 x 90 mm (L x W x H) Weight: approx. 1,8 kg

ecom-DPH Set for the 4 Pa Test

ecom-DPH Measuring Instrument

Graphic-capable display with window approx. 43 x 28 mm, resolution 128 x 64 Pixel, backlit

Power supply: 3 current batteries 1.5V (Mignon) or 3 accumulators 1.2V AA NiCd (nickel-cadmium) or 3 accumulators 1.2V AA NiMh (metal-hydride)

Accumulator charging and instrument operation possible via current USB charger

Dimensions: approx. 170 x 75 x 35 mm (L x B x H) Weight: approx. 300 g

Delivered with 3 batteries, manual and calibration certificate
2 capillary hoses, length approx. 3 m, made out of plastics
With robust transport case made out of plastics

Dimensions (L x B x H): approx. 390 x 345 x 90 mm Weight: approx. 1,0 kg

The ecom-DPH for 4 Pa Test is also available alone (item no. 100734) without transport case. Users of an ecom-CN handheld flue gas analyzer with aluminum-framed transport case will easily store their ecom-DPH in the case and be able to sue the optional infrared printer for both instruments.

ecom-DPH Set for the Heating Check and 4 Pa Test

ecom-DPH Measuring Instrument

Measured values: temperature (-50… 300°C), differential pressure (± 10 hPa)

Calculated value: air speed (0,15 m/s… 40 m/s), ventilation and surface losses

Graphic-capable display with window ≈ 43 x 28 mm, resolution 128 x 64 Pixel, backlit

Power supply: 3 current batteries 1.5V (Mignon) or 3 accumulators 1.2V AA NiCd (nickel-cadmium) or 3 accumulators 1.2V AA NiMh (metal-hydride)

Accumulator charging and instrument operation possible via current USB charger

Dimensions: approx. 170 x 75 x 35 mm (L x B x H) Weigh:t approx. 300 g

Probe for ventilation losses measurement:

Length approx. 250 mm, probe pipe made out of special steel, with cable 2,6 m and fixation cone

Probe for Surface Losses:
with thermocouple strip, length approx. 210 mm (incl. grip), Ø ≈ 16 mm. With cable approx. 1 m (angled probe for hardly accessible measurement points, optional) magnet fixation for surface losses probe, straight style

2 capillary hoses for 4 Pa Test:
length approx. 3 m, made out of plastics

Set delivered in robust transport case made out of plastics

Dimensions: approx. 390 x 345 x 90 mm (L x W x H) Weight: approx. 1,9 kg

 